Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Toxicol Pharmacol ; 99: 104086, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36842547

RESUMO

Micro and nanoplastics are ubiquitous pollutants that can cause adverse health effects even in humans. Effects of virgin and oxidised (simulating the aging processes) polystyrene nano (nPS) and micro particles (mPS) with diameters of 0.1 and 1 µm were studied on human professional phagocytes (i.e., monocyte cells THP-1 and macrophage-like mTHP-1 cells). After characterization by ATR-FTIR, UV-Vis spectroscopy, SEM and dynamic light-scattering analyses, the particles were FITC functionalised to quantify cellular uptake. Changes in the cell compartments were studied by acrydine orange and the pro-oxidant, cytotoxic and genotoxic effects were assessed. Phagocytosis was dose- and time- dependent and at 24 h 52% of nPS and 58% of mPS were engulfed. Despite the high homeostasis of professional phagocytes, significant ROS increases and DNA damage were observed after exposure to oxidised particles. The results highlight that the environmental aging processes enhances the adverse health effects of micro and nanoplastics.


Assuntos
Microplásticos , Poluentes Químicos da Água , Humanos , Microplásticos/toxicidade , Plásticos , Poliestirenos/toxicidade , Espécies Reativas de Oxigênio , Fagócitos/química , Poluentes Químicos da Água/toxicidade
2.
Nanomaterials (Basel) ; 13(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36616127

RESUMO

Nanocomposites formed by aluminum-doped zinc oxide nanoparticles (AZO-NP) and multiwall carbon nanotubes (CNT) are proposed here as a promising material for UV light sensing applications, with the great advantage of operating in air, at room temperature, and at low voltage. Nanocomposite layers were prepared with different AZO:CNT weight ratios by a simple methodology at room temperature. They were characterized by means of UV-Vis spectroscopy, scanning and transmission electron microscopies (SEM and TEM), and X-ray photoelectron spectroscopy (XPS). The interaction between the two nanomaterials was demonstrated by comparing the properties of the nanocomposite with the ones shown by the AZO-NPs. Dense AZO-CNT nanocomposite layers were deposited between two metal electrodes on a SiO2/Si substrate, and the electrical properties were investigated in dark condition and under UV light irradiation. The electrical response to the UV light was a sudden current increase that reduced when the light was switched off. Several UV on/off cycles were performed, showing good repeatability and stability of the response. The mechanisms involved in the electrical response are discussed and compared to the ones previously reported for ZnO-CNT nanocomposites.

3.
Int J Mol Sci ; 23(19)2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36233077

RESUMO

In this work, we coated polypropylene (PP) fibrous filters with sulfonated pentablock copolymer (s-PBC) layers and tested them for the removal of cationic organic dyes, such as methylene blue (MB), and heavy metal ions (Fe3+ and Co2+) from water by adsorption and filtration experiments. Some of the coated filters were irradiated by UV light before being exposed to contaminated water and then were tested with unirradiated filters in the same adsorption and filtration experiments. Polymer-coated filters showed high efficiency in removing MB from an aqueous solution in both absorption and filtration processes, with 90% and 80% removal, respectively. On the other hand, for heavy metal ions (Fe3+ and Co2+), the coated filters showed a better removal performance in the filtration process than for the adsorption one. In fact, in the adsorption process, controlled interaction times allow the ionic species to interact with the surface of the filters leading to the formation and release of new species in solution. During filtration, the ionic species are easily trapped in the filters, in particular by UV modified filters, and we observed for Fe3+ ions a total removal (>99%) in a single filtration process and for Co2+ ions a larger removal with respect to the untreated filter. The mechanisms involved in the removal of the contaminants processes were investigated by characterizing the filters before and after use by means of scanning electron microscopy (SEM) combined with energy-dispersive X-ray (EDX) analysis and Fourier transform infrared spectroscopy (FT-IR).


Assuntos
Metais Pesados , Poluentes Químicos da Água , Adsorção , Alcanossulfonatos , Corantes/química , Íons , Cinética , Metais Pesados/química , Azul de Metileno , Polímeros , Polipropilenos , Espectroscopia de Infravermelho com Transformada de Fourier , Água , Poluentes Químicos da Água/química
4.
Molecules ; 27(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36080476

RESUMO

In recent years thanks to the Internet of Things (IoT), the demand for the development of miniaturized and wearable sensors has skyrocketed. Among them, novel sensors for wearable medical devices are mostly needed. The aim of this review is to summarize the advancements in this field from current points of view, focusing on sensors embedded into textile fabrics. Indeed, they are portable, lightweight, and the best candidates for monitoring biometric parameters. The possibility of integrating chemical sensors into textiles has opened new markets in smart clothing. Many examples of these systems are represented by color-changing materials due to their capability of altering optical properties, including absorption, reflectance, and scattering, in response to different external stimuli (temperature, humidity, pH, or chemicals). With the goal of smart health monitoring, nanosized sol-gel precursors, bringing coupling agents into their chemical structure, were used to modify halochromic dyestuffs, both minimizing leaching from the treated surfaces and increasing photostability for the development of stimuli-responsive sensors. The literature about the sensing properties of functionalized halochromic azo dyestuffs applied to textile fabrics is reviewed to understand their potential for achieving remote monitoring of health parameters. Finally, challenges and future perspectives are discussed to envisage the developed strategies for the next generation of functionalized halochromic dyestuffs with biocompatible and real-time stimuli-responsive capabilities.


Assuntos
Polímeros Responsivos a Estímulos , Dispositivos Eletrônicos Vestíveis , Atenção à Saúde , Estudos Prospectivos , Estudos Retrospectivos , Têxteis
5.
Microorganisms ; 10(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35630315

RESUMO

Legionella pneumophila contamination of water systems is a crucial issue for public health. The pathogen is able to persist in water as free-living planktonic bacteria or to grow within biofilms that adhere to and clog filters and pipes in a water system, reducing its lifespan and, in the case of hospital buildings, increasing the risk of nosocomial infections. The implementation of water management is considered to be the main prevention measure and can be achieved from the optimization of water system architecture, notably introducing new materials and strategies to contrast Legionella biofilm proliferation and so prolong the water system functionality. In this research, we propose a new smart surface against L. pneumophila biofilm formation. This is based on an innovative type of coating consisting of a sulfonated pentablock copolymer (s-PBC, commercially named Nexar™) deposited on top of a polypropylene (PP) coupon in a sandwich filter model. The covering of PP with s-PBC results in a more hydrophilic, acid, and negatively charged surface that induces microbial physiological inhibition thereby preventing adhesion and/or proliferation attempts of L. pneumophila prior to the biofilm formation. The antibiofilm property has been investigated by a Zone of Inhibition test and an in vitro biofilm formation analysis. Filtration tests have been performed as representative of possible applications for s-PBC coating. Results are reported and discussed.

6.
Materials (Basel) ; 14(13)2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34279246

RESUMO

In this work, raw halloysite mineral from Dunino (Poland) has been characterized and tested as an efficient and low-cost adsorbent for dye removal from water. The morphology and structure of this clay were characterized using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) and the chemical composition was evaluated by means of X-ray fluorescence spectroscopy (XRF), energy dispersive X-ray spectroscopy (EDX), and electron energy loss spectroscopy (EELS). The results showed that it is made up of both platy and tubular structures, mainly composed of Si, Al, and O. Iron oxide particles covering the platy structures were also observed. The surface charge of halloysite was measured by z-potential measurements and by the evaluation of the point of zero charge. The clay was tested as an adsorbent for the removal of positively and negatively charged dye molecules, i.e., methylene blue (MB) and methyl orange (MO), both separately and in a mixed-dye solution. Halloysite showed the ability to efficiently and selectively remove MB molecules by adsorption, both in a single-dye solution and in a mixed one. The adsorption of positive dyes on the clay surface mainly occurred through ion exchange at negatively charged sites on its surface. The possibility of regenerating the clay for further dye removal processes is also shown.

7.
Artigo em Inglês | MEDLINE | ID: mdl-34300030

RESUMO

Conventional high throughput methods assaying the chemical state of water and the risk of heavy metal accumulation share common constraints of long and expensive analytical procedures and dedicated laboratories due to the typical bulky instrumentation. To overcome these limitations, a miniaturized optical system for the detection and quantification of inorganic mercury (Hg2+) in water was developed. Combining the bioactivity of a light-emitting mercury-specific engineered Escherichia coli-used as sensing element-with the optical performance of small size and inexpensive Silicon Photomultiplier (SiPM)-used as detector-the system is able to detect mercury in low volumes of water down to the concentration of 1 µg L-1, which is the tolerance value indicated by the World Health Organization (WHO), providing a highly sensitive and miniaturized tool for in situ water quality analysis.


Assuntos
Mercúrio , Poluentes Químicos da Água , Escherichia coli/genética , Mercúrio/análise , Água , Poluentes Químicos da Água/análise , Qualidade da Água
8.
Microorganisms ; 9(3)2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33799845

RESUMO

Legionella is able to remain in water as free-living planktonic bacteria or to grow within biofilms that adhere to the pipes. It is also able to enter amoebas or to switch into a viable but not culturable (VBNC) state, which contributes to its resistance to harsh conditions and hinders its detection in water. Factors regulating Legionella growth, such as environmental conditions, type and concentration of available organic and inorganic nutrients, presence of protozoa, spatial location of microorganisms, metal plumbing components, and associated corrosion products are important for Legionella survival and growth. Finally, water treatment and distribution conditions may affect each of these factors. A deeper comprehension of Legionella interactions in water distribution systems with the environmental conditions is needed for better control of the colonization. To this purpose, the implementation of water management plans is the main prevention measure against Legionella. A water management program requires coordination among building managers, health care providers, and Public Health professionals. The review reports a comprehensive view of the state of the art and the promising perspectives of both monitoring and disinfection methods against Legionella in water, focusing on the main current challenges concerning the Public Health sector.

9.
Molecules ; 25(21)2020 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-33171674

RESUMO

Biological contamination is a typical issue in water treatment. Highly concentrated microbial suspensions in a water flow may cause filter occlusion and biofilm formation, affecting the lifespan and quality of water purification systems and increasing the risk of nosocomial infections. In order to contrast the biofilm formation, most of the conventional strategies rely on the water chemical modification and/or on the use of filters functional coatings. The former is unsafe for huge chemicals spilling required; therefore, we focus on the second approach and we propose the use of a sulfonated pentablock copolymer (s-PBC, commercially named Nexar™) as innovative multifunctional coating for improving the performance of commercial water filters. S-PBC-coated polypropylene (PP) samples were tested against the pathogen Pseudomonas aeruginosa. The covering of PP with s-PBC results in a more hydrophilic, acid, and negatively charged surface. These properties avoid the adhesion and proliferation attempts of planktonic bacteria, i.e., the biofilm formation. Inhibition tests were performed on the as-modified filters and an evident antibacterial activity was observed. The results point out the possibility of using NexarTM as coating layer for filters with antifouling properties and a simultaneous ability to remove bacteria and cationic dyes from water.


Assuntos
Anti-Infecciosos/química , Biofilmes , Materiais Revestidos Biocompatíveis/química , Polipropilenos/química , Anti-Infecciosos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Técnicas de Cultura de Células , Filtração , Teste de Materiais , Viabilidade Microbiana/efeitos dos fármacos , Pseudomonas aeruginosa/efeitos dos fármacos , Água
10.
Nanomaterials (Basel) ; 9(8)2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31370341

RESUMO

Multi-walled carbon nanotubes (CNTs) decorated with zinc oxide nanoparticles (ZnO NPs) were prepared in isopropanol solution by a simple, room-temperature process and characterized from structural, morphological, electronic, and optical points of view. A strong interaction between ZnO and CNTs is fully confirmed by all the characterization techniques. ZnO-CNTs nanocomposites, with different weight ratios, were deposited as a dense layer between two electrodes, in order to investigate the electrical behaviour. In particular, the electrical response of the nanocomposite layers to UV light irradiation was recorded for a fixed voltage: As the device is exposed to the UV lamp, a sharp current drop takes place and then an increase is observed as the irradiation is stopped. The effect can be explained by adsorption and desorption phenomena taking place on the ZnO nanoparticle surface under irradiation and by charge transfer between ZnO and CNTs, thanks to the strong interaction between the two nanomaterials. The nanocomposite material shows good sensitivity and fast response to UV irradiation. Room temperature and low-cost processes used for the device preparation combined with room temperature and low voltage operational conditions make this methodology very promising for large scale UV detectors applications.

11.
Biomed Opt Express ; 9(10): 4679-4688, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30319895

RESUMO

In this work, we investigate some major issues for the use of silicon photomultiplier (SiPM) devices in continuous wave functional near-infrared spectroscopy (CW fNIRS). We analyzed the after-pulsing effect, proposing the physical mechanism causing it, and determining its relevance for CW fNIRS. We studied the SiPM transients occurring as the SiPM device goes from the dark (LED in off state) to the illumination (LED in on state) conditions, and vice-versa. Finally, we studied the SiPM SNR in standard CW fNIRS operation.

12.
Sensors (Basel) ; 18(3)2018 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-29495639

RESUMO

The monitoring of water-soluble pollutants is receiving a growing interest from the scientific community. In this context, sulfide anion species S2- and HS- are particularly relevant since they can cause acute and chronic toxicity including neurological effects and at high concentrations, even death. In this study, a new strategy for fast and sensitive optical detection of sulfide species in water samples is described. The method uses an integrated silicon photomultiplier (SiPM) device coupled with the appropriate analytical strategy applied in a plastic microchip with dried reagents on board. More specifically, all sulfide species (H2S, HS- and S2-) in water samples are detected by the fluorescence signal emitted upon the reaction with N,N-dimethyl-phenylenediamine sulfate in the presence of Fe3+, leading to the formation of the fluorescent methylene blue (MB) species. It has been proven that the system herein proposed is able to measure sulfide concentration in a linear range from 0-10 mg L-1 with a sensitivity value of about 6.7 µA mg-1 L and a detection limit of 0.5 mg L-1. A comparison with conventional UV-Vis detection method has been also carried out. Data show a very good linear correlation (R² = 0.98093), proving the effectiveness of the method. Results pave the way toward the development of portable and low-cost device systems for water-soluble sulfide pollutants.

13.
Neurophotonics ; 4(3): 035002, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28983487

RESUMO

We report development, testing, and in vivo characterization of a multichannel optical probe for continuous wave (CW) functional near-infrared spectroscopy (fNIRS) that relies on silicon photomultipliers (SiPMs) detectors. SiPMs are cheap, low voltage, and robust semiconductor light detectors with performances analogous to photomultiplier tubes (PMTs). In contrast with PMTs, SiPMs allow direct contact with the head and transfer of the analog signals through thin cables greatly increasing the system flexibility avoiding optical fibers. The coupling of SiPMs and light-emitting diodes (LEDs) made the optical probe lightweight and robust against motion artifacts. After characterization of SiPM performances, which was proven to provide a noise equivalent power below 3 fW, the apparatus was compared through an in vivo experiment to a commercial system relying on laser diodes, PMTs, and optical fibers for light probing and detection. The optical probes were located over the primary sensorimotor cortex and the similarities between the hemodynamic responses to the contralateral motor task were assessed. When compared to other state-of-the-art wearable fNIRS systems, where photodiode detectors are employed, the single photon sensitivity and dynamic range of SiPMs can fully exploit the long and variable interoptode distances needed for correct estimation of brain hemodynamics using CW-fNIRS.

14.
Biomed Opt Express ; 7(4): 1183-92, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27486551

RESUMO

We experimentally analyze the signal-to-noise ratio of continuous wave (CW) near infrared spectroscopy (NIRS) reflectance systems based on light emitting diodes and silicon photomultipliers for high performance low cost NIRS biomedical systems. We show that under suitable experimental conditions such systems exhibit a high SNR, which allows an SDS of 7 cm, to our knowledge the largest ever demonstrated in a CW-NIRs system.

15.
Sci Rep ; 5: 8354, 2015 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-25667059

RESUMO

We describe a method for the creation of an efficient optical scatter trap by using fully crystalline octahedral Silicon nanoparticles (Si-NPs) of approximately 100 nanometres in size. The light trapping, even when probing an isolated nanoparticle, is revealed by an enormous amplification of the Raman yield of up to 10(8) times that of a similar Si bulk volume. The mechanism conceived and optimised for obtaining such a result was related to the capability of a Si octahedron to trap the light because of its geometrical parameters. Furthermore, Si-NPs act as very efficient light scatterers not only for the direct light beam but also for the trapped light after it escapes the nanoparticle. These two effects are observed, either superimposed or separated, by means of the Raman yield and by photoluminescence enhancements. The inductively coupled plasma synthesis process performed at a temperature of only 50 °C allows for the ubiquitous use of these particles on several substrates for optical and photovoltaic applications.

16.
Langmuir ; 25(11): 6312-8, 2009 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-19317422

RESUMO

Arrays of circular spots of glucose oxidase have been obtained on functionalized silicon oxide by piezoelectric inkjet printing and the enzymatic activity toward glucose recognition has been monitored. The addition of glycerol to the molecular ink allows to obtain high spot definition and resolution (tens of micrometers wide; one molecule tall), but in spite of its well-known structural stabilizing properties, in dynamic conditions it may lead to increased protein stresses. The jetting voltage and pulse length have been found to be critical factors for both activity retention and pattern definition. High voltages and pulse lengths results in stress effects along with the loss of activity, which, at least in our experimental conditions, has been found to be recovered in time.


Assuntos
Glucose Oxidase/química , Tinta , Análise Serial de Proteínas , Glicerol/química , Microscopia Eletrônica de Varredura , Relação Estrutura-Atividade , Propriedades de Superfície
17.
Sensors (Basel) ; 9(5): 3469-90, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22412322

RESUMO

The aim of this paper is to summarize the efforts carried out so far in the fabrication of Si-based biosensors by a team of researchers in Catania, Italy. This work was born as a collaboration between the Catania section of the Microelectronic and Microsystem Institute (IMM) of the CNR, the Surfaces and Interfaces laboratory (SUPERLAB) of the Consorzio Catania Ricerche and two departments at the University of Catania: the Biomedical Science and the Biological Chemistry and Molecular Biology Departments. The first goal of our study was the definition and optimization of an immobilization protocol capable of bonding the biological sensing element on a Si-based surface via covalent chemical bonds. We chose SiO(2) as the anchoring surface due to its biocompatibility and extensive presence in microelectronic devices. The immobilization protocol was tested and optimized, introducing a new step, oxide activation, using techniques compatible with microelectronic processing. The importance of the added step is described by the experimental results. We also tested different biological molecule concentrations in the immobilization solutions and the effects on the immobilized layer. Finally a MOS-like structure was designed and fabricated to test an electrical transduction mechanism. The results obtained so far and the possible evolution of the research field are described in this review paper.

18.
Langmuir ; 24(5): 1965-72, 2008 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-18205419

RESUMO

A process to immobilize the enzyme glucose oxidase on SiO2 surfaces for the realization of integrated microbiosensors was developed. The sample characterization was performed by monitoring, step by step, oxide activation, silanization, linker molecule (glutaraldehyde) deposition, and enzyme immobilization by means of XPS, AFM, and contact angle measurements. The control of the environment during the procedure, to prevent silane polymerization, and the use of oxide activation to obtain a uniform enzyme layer are issues of crucial importance. The correct protocol application gives a uniform layer of the linker molecule and the maximum sample surface coverage. This result is fundamental for maximizing the enzyme bonding sites on the sample surface and achieving the maximum surface coverage. Thin SiO2 layers thermally grown on a Si substrate were used. The XPS Si 2p signal of the substrate was monitored during immobilization. Such a signal is not completely shielded by the thin oxide layer and it is fully suppressed after the completion of the whole protocol. A power spectral density analysis on the AFM measurements showed the crucial role of both the oxide activation and the intermediate steps (silanization and linker molecule deposition) to obtain uniform immobilized enzyme coverage. Finally, enzymatic activity measurements confirmed the suitability of the optimized protocol.


Assuntos
Enzimas Imobilizadas , Glucose Oxidase/química , Dióxido de Silício/química , Elétrons , Microscopia de Força Atômica , Análise Espectral , Propriedades de Superfície , Raios X
19.
Sensors (Basel) ; 8(9): 5637-5648, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-27873833

RESUMO

Silicon dioxide surfaces, both bulk and porous, were used to anchor the enzyme glucose oxidase. The immobilization protocol was optimized and the samples characterized using X-ray Photoelectron Spectroscopy, Energy Dispersive X-rays coupled to scanning electron microscopy and enzymatic activity measurements. We show that a uniform layer was obtained by activating the oxide before immobilization. X-ray Photoelectron Spectroscopy measurements carried out on bulk oxide showed that the silicon substrate signal was fully screened after the enzyme deposition showing the absence of uncovered surface regions. The enzyme presence was detected monitoring both the C 1s and N 1s signals. Finally, enzymatic activity measurements confirmed that the glucose oxidase activity was preserved after immobilization and maintained after three months of shelf life if the sample was properly stored. The importance of using porous silicon oxide to maximize the surface area was also evidenced.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...